Attic ventilation
The most common defect we find isn't on the roof. It's under it.
Unbalanced ventilation shortens shingle life, drives cooling costs, grows mould and quietly voids the warranty you paid for.
How ventilation actually works
An attic needs air moving continuously from low to high: cool air in at the soffits, hot humid air out at the ridge. That's it. When it works, shingles run cooler, moisture doesn't condense on the underside of the deck, and the roof lasts the time it's supposed to.
The rule, and why it gets broken
The general standard is one square foot of net free ventilating area for every 150 square feet of attic floor, or 1:300 with a vapour barrier, split roughly evenly between intake low and exhaust high. Balance matters more than total: a big ridge vent with blocked soffits doesn't ventilate, it just pulls conditioned air out of your house through every gap in the ceiling.
Almost every under-ventilated attic we open in this region has the same cause — insulation pushed into the eaves during an energy upgrade, blocking the soffit intake completely.
What it costs you
- Shingles cooking from beneath, which ages them years faster than sunlight alone
- Manufacturer warranties denied, because nearly all of them require adequate ventilation
- Condensation on the deck underside in winter, then delamination and mould
- Ice damming on the rare Georgia freeze, in the valleys and at the eaves
- Cooling costs climbing as a 150-degree attic sits on top of your ceiling insulation
Signs your attic isn't breathing
- Attic noticeably hotter than outside air on a summer afternoon
- Frost or damp on the underside of the roof deck in winter
- Dark staining or mould signature on the sheathing
- Insulation packed tight into the eaves, blocking soffit vents
- Shingles ageing faster on one slope than another
- Upstairs rooms that never cool down
- Bathroom fans ducted into the attic instead of through the roof
Mixing exhaust types backfires
A ridge vent plus powered fans plus gable vents can short-circuit airflow — the fan pulls from the nearest opening rather than from the soffits, and the far end of the attic stops ventilating entirely. More vents is not the same as better ventilation.
What we install
Ridge ventilation
Continuous externally baffled ridge vent, cut to the correct slot width. The most effective exhaust for most homes.
Soffit intake
Continuous or individual soffit vents, plus baffles to keep insulation out of the airway.
Baffles & chutes
Installed at every rafter bay so the intake path stays open after the next insulation upgrade.
Solar attic fans
Where roof geometry can't support enough ridge line. Used deliberately, not as a default.
Bath fan ducting
Vented properly through the roof with an insulated duct and a damper — never dumped into the attic.
Ventilation calculation
Attic area measured, net free area calculated, and the design written into your estimate.
Common questions
Do I need a powered attic fan?
My attic has gable vents. Is that enough?
Can this be fixed without replacing the roof?
Will better ventilation lower my power bill?
Request your free inspection
Tell us about the property and we'll come out with a camera, a moisture meter and a written number.
Upstairs never cools down?
We measure the attic and calculate the actual net free area rather than guessing at vent count.